SONG technical management tasks page

Update status of task:
Description of task:Power failure at the observatory. A number of issues: main server did not boot up. Later no connection to the weather station board

Updated by
(Re)assign to
New status
Comment
Expected handled on Expected to be handled on? [YYYY-MM-DD]


Old comments:

2022-12-13 08:17: [Mads]: Weather station board had a failing power supply (PSU5) providing power for the two moxa units. This was located and a replacement was found in the container.

Managed to find the login credentials for ss5drac interface and boot up ss5n1. Then no connection to the weather station moxas indicating a failure in the multi socket power board.