SONG technical management tasks page

Details of SONG task
Insertion dateTaskResponsibleLevel
2022-12-12 Power failure at the observatory. A number of issues: main server did not boot up. Later no connection to the weather station board Mads Critical

Handled dateCommentHandled byTask ID
2022-12-13 2022-12-13 08:17: [Mads]: Weather station board had a failing power supply (PSU5) providing power for the two moxa units. This was located and a replacement was found in the container.

Managed to find the login credentials for ss5drac interface and boot up ss5n1. Then no connection to the weather station moxas indicating a failure in the multi socket power board.
Mads 154